 Modular Radio Telemetry System
200 Series
* * * * * * *
Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic `Watchdog' Transmission
* Range:
Upto 200 metres at 433MHz Upto 1,000 metres at 433MHz Narrow Band. Upto 6,000 metres at 458MHz * Requires no radio license
* Relay Outputs upto 30A @ 230Vac * All Modules supplied with Antenna
Remote Telemetry Systems are well suited to industrial switching applications where telemetry signals need to be sent remotely from one location to another. This system allows multiple transmitters to a single receiver or a single transmitter to multiple receivers. Each Transmitter module accepts upto 8 pairs of `Volt Free' contacts as inputs via screw terminals. Each Receiver has 16 outputs arranged as 4 x 4 easy plug in connectors to interface to any combination of output modules. Any of the output modules connect directly to the receiver (cable supplied) to provide transistor switching or relay outputs.
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 1
Modular Radio Telemetry System
Transmitters
200 Series
* * * *
8 Input Channels Volt Free contact Inputs via Screw Terminals 12 / 24Vdc Supply Low Power Battery Version Standard transmitter Low Power Transmitter . (Designed for battery powered applications) Description FM Transmitter FM Narrow Band Transmitter FM High Power Transmitter FM Narrow Band Transmitter FM High Power Transmitter Range** (Metres) 200 1,000 6,000 1,000 6,000 Freq (MHz) 433.92 434.525 458.850 434.525 458.850 Compatible Decoders 210-433F 210-525N 210-458F 210- 525N 210-458F
200 Transmitter: 201 Transmitter: Part Number 200-433FR 200-525NR 200-458FR 201-525NR 201-458FR
Receivers
* * * *
16 Output Channels Volt Free contact Inputs via Screw Terminals 12 / 24Vdc Supply Low Power Battery Version Part Number Description FM Receiver FM Narrow Band Receiver FM High Power REceiver Range** (Metres) 200 1,000 6,000 Freq (MHz) 433.92 434.525 458.850 Compatible Transmitter 200/201-433F 200/201-525N 200/201-458F
210-433FR 210-525NR 210-458FR
Output Modules
* *
Connect Directly to 210 Rx (Cable Supplied) no power connections required Part Number 211 215 216 230 Description Darlington Driver Outputs Relay Module Relay Module Relays Module No of Outputs 16 8 4 4 Max Switching (per output) 0.5A @ 50V (Overall total 1A) 5A @230Vac 5A @230Vac 30A @230Vac
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 2
Modular Radio Telemetry System
Enclosure / Power Supply
200 Series
* * *
IP56 Insulation Class 2 DIN Rails mounted on Steel Plate 12Vdc 1A PSU incorporated accepts 110-240Vac (5A Fused)
Dimensions
External Internal DIN Rail length 1 DIN Rail length 2 315 x 235 x 130mm 300 x 220 x 120mm 285mm 180mm
Part No ENC-DA3 PSU12V1AIN-IP
Description DIN Rail Enclosure Assembly, Two Mounting Rails, 12Vdc PSU Fitted Power Supply 110-240Vac input, 12Vdc 1A Output
Custom systems We regularly supply pre-wired / bespoke systems, please contact our sales dept for further assistance
R. F. Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E Sussex, BN8 6JL. England Tel +44 (0)1273 898 000 Email sales@rfsolutions.co.uk Fax +44 (0)1273 480 661 http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions products as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 3
Modular Radio Telemetry System
200 Series
1 Configuring a Remote Telemetry System
(200Tx/201Tx -> 210Rx)
There are three Steps: 1. Pre-Configure the 200 or 201 series transmitter 2. Pre- Configure the 210Rx to operate with a 200 or 201 series transmitter 3. Marry a 200/201Tx to a 210Rx
1.1
Pre-Configure a 200/201 Transmitter Encoder
1. Mapping the 200/201 Transmitter Inputs to the 210 Receiver Outputs The Remote telemetry system automatically maps the 8 transmitter input channels to 8 receiver output channels. The `8/15' option link on the transmitter allows selection of channels 1-8 or 9-15 on the receiver. 200/201 Tx Option Link Open Connected 210 Rx output Channels 1-8 9 - 15
2. Enable Option Links (ENABLE 1-8) The 200 and 201 Transmitters have eight `Enable' Option links which must be fitted in order for the corresponding input to be valid (otherwise the 210Tx will ignore it). This enables applications where many transmitters are used with a single 210Rx (many to one relationship) 3. Auto Transmit with Watchdog Mode `Auto Tx' When the `Auto Tx' link is made, the 200/201 Tx automatically transmits its data once within every 5 second period, in addition, channel 16 is allocated as a `system watchdog`. As long as the 210Rx continues to receive this signal then output `16' is held ON. If for any reason (fault or RF interference) the signal is not received for approx 20secs then output `16' will drop out.
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 4
Modular Radio Telemetry System
1.2
200 Series
Pre-Configure a 210Rx to operate with a 200/201 Tx series transmitter
Ensure option link J8 is open. Apply power to the 210Rx, All output LEDS flash alternately. This is factory reset default state. Apply power to any 200 or 201 Tx and briefly operate any input by shorting any of the input terminals on the transmitter (ensure Enable link is fitted!), to force a transmit. 4. The 210Rx. LED2 flashes 5 times to indicate that the 210Rx is now configured for use with 200 / 201Tx. 5. Each time power is applied the 210Rx, LED2 flashes 5 times to show it is configured to operate with 200Tx transmitters. 6. Configuration is now complete and 200/201 transmitter unit(s) can be learned to the 210Rx receiver. Note: Option links LK 1-16 have no affect on the operation of the remote telemetry system.
1. 2. 3.
1.3
1. 2. 3. 4. 5. 6. 7. 8.
Marry a 200/201 Tx to a 210Rx
On the 200/201 Tx, remove the Link header `OPT1` (auto Tx). (prevents automatic transmission during the learn process). On the 210Rx Ensure option link J8 is open. Apply power to the 210Rx, note that LED2 flashes 5 times to show it is configured for use with 200Tx transmitters. Briefly press the 210Rx Learn Switch: Note that the 210Rx Learn LED (LED 17) will flash. Wait until the 210Rx Learn LED has stopped flashing but is still illuminated. Apply power to any 200/201 Tx and briefly operate any input by shorting any of the input terminals on the Transmitter (ensure Enable link is fitted!), to force a transmit. Note that the 210Rx learn LED will turn off. The learn cycle is now complete and the transmitter/encoder will operate the systems.
1.4
1. 2. 3. 4.
Erasing the 210Rx Receiver Outputs (Return to Factory Default State)
To completely erase the 210Rx decoder's memory, press and hold the 210Rx learn switch. The learn LED will illuminate Hold the learn switch until the learn LED extinguishes (approx 10 seconds). Release the learn button and all the output LED's will now flash alternately to indicate that all encoder data has been erased and the 210Rx has returned to factory default state. Note: It is not possible erase individual transmitters.
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 5
Modular Radio Telemetry System
1.5 Connecting output Modules to the 210 Receiver
200 Series
A range of `200' series output modules are available which can be plugged into the 210 Receiver via the four IDC header boxes on the receiver. The selection of output module will be dependant on the application. Please see DS200S-1 for a summary the available modules.
1.6
Connecting an Antenna
The 210Rx has a 200mm flying lead cable (50ohm) with a panel mount BNC socket provided to mount on an enclosure. This cable may be extended however please note that typically there is a 50% range reduction with every 3metres of coax cable used! For increasing range performance a +3dB gain antenna is available. This is supplied with wall mounting bracket and 2metres of coax cable, it plugs in directly to the 210Rx BNC connector.
1.7
Range
The antenna choice and position directly controls the system range. Keep it clear of other metal in the system. The best position by far, is protruding from the top of the product. This is often not desirable for practical or ergonomic reasons and thus a compromise may be needed. If an internal antenna must be used then try to keep it away from other metal items, and in particular large ones like transformers, batteries and PCB tracks and earth planes. Note that the space around the antenna is as important as the antenna itself. All radio systems are dependant on a radio signal being received through airspace. The range quoted is the optimal in direct line of sight without obstacles and in good atmospheric conditions. Range is affected by many things, for example local environmental conditions, atmospheric conditions, interference from other radio transmitters. For evaluating the local environment please see our RF Meter (DS006) In very worse case applications the range quoted may be reduced to 30% of the optimal range stated.
1.8
Signal integrity
In systems where many encoders are in close proximity there may be occasions when, due to signal overlay between encoders, it is difficult or impossible to guarantee system integrity. In such circumstances it is the responsibility of the installer to ensure that the system performance is adequate for the purposes of the installation.
1.9
Information availability
All products are supplied with their relevant datasheets. These are also available for download from the website or on request from RF Solutions Ltd.
R. F. Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E. Sussex, BN8 6JL, England Tel +44 (0)1273 898 000 Email sales@rfsolutions.co.uk Fax +44 (0)1273 480 661 http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association All Trademarks acknowledged and remain the property of the respected owners
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 6
Modular Radio Telemetry System
Module Technical Specifications Transmitters
* * * *
8 Input Channels Volt Free contact Inputs via Screw Terminals 12 / 24Vdc Supply Range; 433MHz up to 433MHz NB up to 458MHz up to High Security RF Protocol Low Power Battery Version Auto Transmit Mode Automatic `Watchdog' Transmission Antenna Supplied 200 Metres 1,000 Metres 6,000 Metres
200 Series
* * * * *
BNC Socket
This is a simple to use radio transmitter module which can accept 8 pairs of `Volt free' contacts inputs. When an input occurs the transmitter will transmit a data packet over the RF link to an associated receiver. (That has been learnt into the transmitter). The transmitter continually monitors the status of its `inputs'. It transmits a signal on any input change and also can be set to transmit automatically every 15 seconds . Full configuration instructions are given further in this document.
I/P 1
Auto Tx
I/P 2
I/P 3
I/P 4
Enable 1-8
8 / 15
200/201 Transmitter
I/P 8
RF Tx
I/P 5
I/P 6
I/P 7
12 / 24Vdc Supply
8 x Zero Volt Inputs
200 Transmitter: 201 Transmitter:
Standard transmitter Low Power Transmitter . (Designed for battery powered applications)
Part Numbering
Part Number 200-433FR 200-525NR 200-458FR 201-525NR Description FM Transmitter FM Narrow Band Transmitter FM High Power Transmitter FM Narrow Band Transmitter Range** (Metres) 200 1,000 6,000 1,000 Freq (MHz) 433.92 434.525 458.850 434.525 Compatible Decoders 210-433F 210-525N 210-458F 210- 525N
201-458FR FM High Power Transmitter 6,000 458.850 210-458F ** Range stated is optimum, direct line of sight. In worst conditions this can be reduced by upto 50%
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 7
Modular Radio Telemetry System
Technical Specifications
Dimensions: Within DIN Rail: 200Tx : 112 x 82 mm (PCB: 109 x 72mm) 201Tx 160 x 82 mm (PCB: 145 x 72mm) Storage Temperature; -10 to +155o C Operating Temperature; -0 to +55o Celsius. Electrical Characteristics Min Typical Supply Voltage: 12V Supply 10 12 Supply Voltage: 24V Supply 21 24 Antenna Output Lead Impedance 50 Minimum input activation time to trigger transmission 5 433MHz / 433NBMHz Version Supply Current: Quiescent 10 Supply Current: Transmitting Data 150 170 458MHZ Version Supply Current: Quiescent 10 Supply Current: Transmitting Data 240 250
200 Series
Max 16 30
Units V V Ohms ms mA mA mA mA
200
270
200 Transmitter Current Consumption 433MHz / 433NBMHz Version Supply Current: Quiescent Supply Current: Transmitting Data 458MHZ Version Supply Current: Quiescent Supply Current: Transmitting Data 201 Transmitter Current Consumption Supply Current: Quiescent Supply Current: Transmitting - 433MHz NB module Supply Current: Transmitting - 458MHz module
Min
Typical 10 170 10 250 Typical 60 50 180
Max
Units mA mA mA mA Units nA mA mA
150
200
240 Min
270 Max
R. F. Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E. Sussex, BN8 6JL, England Tel +44 (0)1273 898 000 Email sales@rfsolutions.co.uk Fax +44 (0)1273 480 661 http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 8
Modular Radio Telemetry System
Receivers
This DIN rail module performs the radio reception and decoding for the 200 series modules. It has four output connectors each with four digital outputs and displays the output status on LED's 1-16. Any of the DIN Rail output modules lug into these connectors marked 1-4 (Connecting cable supplied with output module).
200 Series
Connector 1 2 3 4
O/P Channels 1-4 5-8 9 - 12 13 - 16
BNC Socket
12 / 24Vdc Supply
210Rx
O/P 13-16
O/P 9-12
O/P 5-8
O/P 1-4
Technical Specifications
Dimensions: Within DIN Rail: 138 x 82 mm (PCB: 133 x 72mm) Storage Temperature: -10 to +70o Celsius. Operating Temperature: 0 to +55o Celsius. Electrical Characteristics Min Typical Supply Voltage: 12V Supply 10 12 Supply Voltage: 24V Supply 21 24 Supply Current : Quiescent 25 Time from Tx Switch depressed to 210Rx output Time from Tx Switch release to Decoder output Switched output Voltage (I out = 1mA) Logic Low 0 0.2 Logic High 3.5 3.8
Connects to any Output Module
Max 16 30 100 200 0.8 5
Units V V mA mSecs mSecs V V
Part Numbering
Part No 210-433FR 210-525NR 210-458FR Description Receiver Decoder 16 Channels DIN Rail Mounting, FM @ 433.92MHz Receiver Decoder 16 Channels DIN Rail Mounting, FM Narrow Band @ 434.525MHz Receiver Decoder 16 Channels DIN Rail Mounting, FM High Power @ 458.850MHz
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 9
Modular Radio Telemetry System
Output Modules
211 Darlington Output
* * * * 16 transistor switch outputs Each Output switches to GND when operated Each output rated 500mA at up to 50Vdc Total cumulative output of module 1A @50Vdc
200 Series
Switched Outputs 1-4
Switched Outputs 9-12
Ground Connections
210 Rx
211
The only connections required are * Screw terminals to connect to each channel output. * Direct connection to the 210 Receiver via the four ribbon cables / connectors supplied.
Switched Outputs 5-8
Switched Outputs 13-16
Dimensions: Within DIN Rail: 70 x 82mm (PCB: 64 x 72mm) Storage Temperature: -10 to +70o Celsius. Operating Temperature: 0 to +55o Celsius. Electrical Characteristics Min Typical Max Supply Voltage From 210Rx module Output voltage 50 Continuous current Load: Per Channel 500 Total module 1,000
Units VDC mA mA
`215' Relay Output Module
8 relay switches rated 230Vac at 5A Each relay provides `input' and `normally open' screw terminals The only connections required are * Connection to the 210 Receiver via the ribbon cable supplied. * Connection to each relay via screw terminals provided. * *
Relay Outputs 1 - 4
210 Rx
215
Dimensions: Within DIN Rail: 93 x 82 mm (PCB: 90 x 72mm) Storage Temperature: -10 to +70o Celsius. Operating Temperature: 0 to +55o Celsius. Electrical Characteristics Min Typical Max Units Supply Voltage From 210Rx module Relay* output Rating Max rating is 3A/220VAC/30VDC Type HRS1KH3-12 *The relay contacts in this unit are for functional use only and must not be used for isolation purposes
Relay Outputs 5 - 8
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 10
Modular Radio Telemetry System
216 Relay Output Module
* * 4 relay outputs rated at 230Vac ,12A peak and 5A continuous current rating. `normally open' and `normally closed' screw terminals.
210 Rx
200 Series
216
Relay Outputs 1 - 4
Dimensions: Within DIN Rail: 135 x 82 mm (PCB: 132 x 72mm) Storage Temperature: -10 to +70o Celsius. Operating Temperature: 0 to +55o Celsius. Electrical Characteristics Min Typical Max Units Supply Voltage From 210Rx module Relay* output Rating (type KB12) at 230Vac 5 12 A *The relay contacts in this unit are for functional use only and must not be used for isolation purposes
230 Relay Output Module
* *
210 Rx
4 relay (type K7SFA12) outputs rated for up to 30A at 230Vac. Each relay provides `input' and `normally open' Spade Terminals.
230
Relay Outputs 1 - 4
Dimensions: Within DIN Rail: 115 x 82 mm (PCB: 109 x 72mm) Storage Temperature: -10 to +70o Celsius. Operating Temperature: 0 to +55o Celsius. Electrical Characteristics Min Typical Max Units Supply Voltage From 210Rx module Relay output Rating @ 230Vac* 30 A @ 12Vdc 20 A *The relay contacts in this unit are for functional use only and must not be used for isolation purposes
R. F. Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E Sussex, BN8 6JL. England Tel +44 (0)1273 898 000 Email sales@rfsolutions.co.uk Fax +44 (0)1273 480 661 http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions products as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS200-11 March '06
(c)2005 RF Solutions Ltd, www.rfsolutions.co.uk Tel 01273 898000 Fax 01273 480661
Page 11


▲Up To Search▲   

 
Price & Availability of 211

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X